ROOF PITCH
The standard roof pitch for The Camden is a 6, & 15/16 to 12 pitch.
DESIGN LOADS
The typical design load allows for:
12 pounds per square foot dead load
30 pounds per square foot live load
20 pounds per square foot wind load. (Equates to 100 MPH)
There are variables that affect the design sizes of the members,
specifically the arches and the purlins, and those variables
generally include live load conditions which are usually location
specific. Building Codes usually dictate the applicable loads to be
applied in the member size designs.
PRESSURE PRESERVATIVE TREATMENT
As noted in the list above, all components are treated: the wood
arches, beams and purlins, wall and roof decking, and the fascia are
fabricated with lumber pressure treated, with Penta WR Type C (.3
pcf [3 tenths of a pound of preservative per cubic foot of wood]
retention). EnWood utilizes the pentachlorophenol treatment because
of its premier qualities and the treatment does not discolor the
wood and can be stained or painted.
FOR DETAILED SPECIFICATIONS,
PLEASE CLICK ON THE SPECIFICATION LINK
|